Culligan Mark 100 Manuale di Servizio

Navigare online o scaricare Manuale di Servizio per Climatizzatori a split Culligan Mark 100. Culligan Mark 100 Service manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - CCIIRRCCUUIITT BBOOAARRDDSS

Rev. A 09/24/02DCO# 4541Cat. No. 01015170HHOOUUSSEEHHOOLLDD &&CCOOMMMMEERRCCIIAALLCCIIRRCCUUIITT BBOOAARRDDSSModels From 1994 - 2002©2002 Cu

Pagina 2 - TABLE OF CONTENTS

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS8- 3- 43. Press the status key. If a flow meter is plugged into the circuit board, abar on the secon

Pagina 3 - CCiirrccuuiitt BBooaarrdd

CCuulllliiggaann®MMaarrkk 110000 GGeenneerraattiioonn 11 CCiirrccuuiitt BBooaarrddUsed from 7/94 to 6/98Replacement PN: 01-0042-94 - 110 volt01-0

Pagina 4

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS10CCoonnnneeccttiioonnssMeter ConnectionCam ConnectionDip SwitchAqua-SensorConnectionPower Connectio

Pagina 5

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS117. Press status. Set Regeneration Interval (1-42 days).TIME CLOCK MODELS ONLY.3123 456 75. Press s

Pagina 6

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS12CCyycclliinnggThe Culligan®Mark 100 control can be indexed through the various regeneration stages

Pagina 7

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS13CCyycclliinnggFailure ModeThe Culligan Mark 100 control is equipped to detect a motor or piston wh

Pagina 8

CCuulllliiggaann®MMaarrkk 110000 GGeenneerraattiioonn IIII//CCuulllliiggaann PPllaattiinnuumm SSeerriieess GGeenneerraattiioonn II CCiirrccuui

Pagina 9

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS15CCoonnnneeccttiioonnssFIG. 3 - Circuit Board DisplayThe display will initially power up flashing

Pagina 10 - Error Display Cancellation

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS16Press  to increase or to decreasePress  to increase or to decreasePress  to increase or to d

Pagina 11 - CCuulllliiggaann

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS17Press  to increase or to decreasePress  simultaneouslyPress  to change8. Press status again

Pagina 12 - CCoonnnneeccttiioonnss

CCuulllliiggaann HHoouusseehhoolldd aanndd CCoommmmeerrcciiaall CCiirrccuuiitt BBooaarrddssMMooddeellss FFrroomm 11999944 -- 22000022TABLE OF

Pagina 13 - PPrrooggrraammmmiinngg

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS18The service check mode allows one to view the instantaneous flow rate, the days since the last reg

Pagina 14 - CCyycclliinngg

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS19MMaannuuaall CCyycclliinnggThe Culligan®microprocessor can be indexed through the various regener

Pagina 15

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS20BBooaarrdd DDiiaaggnnoossttiiccssTo enter the board test mode, flip all of the dip switches to th

Pagina 16

CCuulllliiggaann SSiillvveerr SSeerriieess™,, CCuulllliiggaann GGoolldd SSeerriieess™,,CCuulllliiggaann® MMaarrkk 110000 GGeenneerraattiioonn

Pagina 17

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS22CCoonnnneeccttiioonnssPress  to increase or to decreasePress  to increase or to decreasePress

Pagina 18

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS23Press  to increase or to decrease5. Pressing status again will show the Salt Dosage. This can b

Pagina 19

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS24MMaannuuaall CCyycclliinnggThe Culligan®microprocessor can be indexed through the various regener

Pagina 20 - SSeerrvviiccee CChheecckk

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS25The service check mode allows one to view the instantaneous flow rate, the days since the last reg

Pagina 21 - MMaannuuaall CCyycclliinngg

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS26To enter the board test mode, flip all of the dip switches to the ON position. All the segments of

Pagina 22

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS27Converting the Culligan Mark 100 Generation I Circuit Board to a Generation III Circuit BoardFamil

Pagina 23

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS1CCuulllliiggaann MMeeddaalllliisstt SSeerriieess™CCiirrccuuiitt BBooaarrddUsed from 1/01 to Curr

Pagina 24

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS28WWiirriinngg SScchheemmaattiicc

Pagina 25

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS29CCuulllliiggaann®AAqquuaa--SSeennssoorr®SSeennssiinngg DDeevviiccee TTrroouubblleesshhoooottiinn

Pagina 26

CCuulllliiggaann®AAqquuaa--SSeennssoorr®SSeennssiinngg DDeevviiccee TTrroouubblleesshhoooottiinngg CCoonnttiinnuueeddProbe TestRun this test only o

Pagina 27

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS31TTrroouubblleesshhoooottiinngg FFlloowwcchhaarrttProblem: Regenerates NeverNightly RegeneratesDia

Pagina 28

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS32CCuulllliiggaann®MMaarrkk 1100 aanndd EEssttaattee 22MM GGeenneerraattiioonn II CCiirrccuui

Pagina 29 - INSTALLATION

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS33CCoonnnneeccttiioonnssDip SwitchesAmber LEDPower ConnectionMeter ConnectionRegen ButtonConnectionR

Pagina 30

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS34CCuulllliiggaann®MMaarrkk 1100 aanndd EEssttaattee 22MM GGeenneerraattiioonn II II CCiirrc

Pagina 31 - AAqquuaa--SSeennssoorr

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS35There are two pilot lights located on the circuit board.• The green pilot light flickers when wate

Pagina 32

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS36IInnssttaallllaattiioonnConverting the Culligan Mark 10/Estate 2M Generation I Circuit Board to a

Pagina 33

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS37Power ValveCAUTION: Refer to the wiring schematic diagram for correct plug in reference of wire h

Pagina 34

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS2FIG. 3 - Circuit Board DisplayPPrrooggrraammmmiinnggMake sure the inlet water supply is turned off,

Pagina 35

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS38Wiring Diagram • Power Valve

Pagina 36

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS39Wiring Diagram • Delrin Valve

Pagina 37

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS40CCuulllliiggaann®CCoommmmeerrcciiaall GGeenneerraattiioonn II CCiirrccuuiitt BBooaarrddUsed

Pagina 38 - IInnssttaallllaattiioonn

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS41CCoonnnneeccttiioonnss®Comm. Connection (Duplexing)Meter ConnectionAqua-SensorConnectionTransforme

Pagina 39 - Parts List

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS42®CCoonnnneeccttiioonnss

Pagina 40 - Wiring Diagram • Power Valve

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS43CCoonnnneeccttiioonnss

Pagina 41 - Wiring Diagram • Delrin Valve

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS441. Turn on the power to the control.2. Display will be flashing.3. Press status twice; 12:00 PM wi

Pagina 42

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS459. Press status again, if the unit is a time-clock model the display will show the number of days

Pagina 43

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS46The service check mode allows one to view the instantaneous flow rate, the days since the last reg

Pagina 44

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS47The Culligan®Electronic control can be indexed through the various regeneration stages. For all s

Pagina 45

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS3OFF4. Timeclock BackupPress the “STATUS” key. The display will blink “dIP4” for 3 seconds and then

Pagina 46

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS48Board DiagnosticTo enter the board test mode, turn all the dip switches to theON position. All se

Pagina 47

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS49CCuulllliiggaann®CCoommmmeerrcciiaall GGeenneerraattiioonn IIII CCiirrccuuiitt BBooaarrddUsed

Pagina 48

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS50CCoonnnneeccttiioonnssSingle Flow Meter & Single AquaSensor®Circuit Board Connections®

Pagina 49

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS51Duplex Parallel Flow Meter Circuit Board ConnectionDuplex Parallel Aqua-Sensor® Circuit Board Conn

Pagina 50 - DDiiaaggnnoossttiicc

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS52Duplex Alternating Aqua-Sensor®Circuit Board Connection (See Fig. 11 for tubing instructions)Duple

Pagina 51

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS531. Turn on the power to the control.2. Display will be flashing.3. Press status twice; 12:00 PM wi

Pagina 52

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS549. Press status again, if the unit is a time-clock model the display will show the number of days

Pagina 53

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS55The service check mode allows one to view the instantaneous flow rate, the days since the last reg

Pagina 54

The Culligan®Electronic control can be indexed through the various regeneration stages. For all steps, thecycle numbers do not appear until the motor

Pagina 55

Board DiagnosticTo enter the board test mode, turn all the dip switches to theON position. All segments of the board will light until either akey is

Pagina 56

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS4Step 3 – Programming Salt DosagePress the “Status” key after programming regeneration time.The disp

Pagina 57

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS5Exiting Program ModeFrom Step 6 (or step 7 if it is active) press the “Status” key.The display will

Pagina 58

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS6H 007:28PM5. Press the “+” key. An 'H' will appear in the display. The unit is inthe H

Pagina 59

CULLIGAN HOUSEHOLD & COMMERCIAL CIRCUIT BOARDS79355. Press the “-” key. The display will blink “totL” for 3 seconds andthen display the total num

Commenti su questo manuale

Nessun commento